The coordinate automatic screw locking machine has strong independence, and equipment protection and maintenance are controlled through the human-machine interface. Equipment faults and malfunctions will be displayed on the touch screen. If the equipment is abnormal, there will be relevant prompts on the control interface. The automatic screw locking machine is a non-standard equipment, and each model has its own control system. The control system is usually programmed independently by the screw machine manufacturer, and the program varies depending on the product. The techniques introduced here are only applicable to coordinate automatic screw locking machines.
1、 Common problems with coordinate automatic screw locking machine
1. The coordinate automatic screw locking machine with a robotic arm is composed of a screw feeding system, a multi axis locking system, an automatic gripping system, and a multi station worktable. The multi system cooperates and synchronizes the work. If there are many problems, please introduce the locking system and gripping system of the automatic screw machine, as well as the problems and solutions in their application.
2. The system cannot be started: check if the start light is normal. If not, check if the start button is clear; Is the magnetic ring on the lifting cylinder normal? If not, check the quality of the magnetic ring and make sure it is clear; Is it in automatic mode; Is the emergency stop light normal? If not, check the emergency stop button and ensure it is clear; Check if the magnetic ring on the robotic arm is functioning properly, and if not, inspect the quality of the magnetic ring and search for clarity.
3. After the system is started, the turntable does not twist: check whether the turntable drive motor is twisted. If not, use the multimeter AC750 gear to measure whether the turntable drive motor and control power supply are clear and whether there is AC220V. If there is voltage, the motor is damaged; Check if the brake and dispersion are activated.
4. During the descent process after the system is started, the electric or pneumatic batch does not rotate: check whether the magnetic ring in the lifting cylinder is normal.
5. Coordinate automatic screw locking machine achieves no upward movement when tightening screws: check if the magnetic ring under the lifting cylinder is normal.
6. Coordinate based automatic screw locking machine does not send screws after the screw is tightened and lifted into place: check whether the screw sending machine is stuck and whether the power and air supply of the screw sending machine are normal; Check if the magnetic ring on the lifting cylinder is normal.
7. Coordinate automatic screw locking machine robot arm not working: check if the function of the robot arm is enabled; Check if it is normal to open the magnetic ring and gripping position magnetic ring on the robotic arm with fingers.
8. The robotic arm cannot grab the product: check if the product is stuck; Check if the finger engagement magnetic ring is normal.
9. The robotic arm does not place the product in the retrieval position: check if the magnetic ring of the robotic arm's retrieval position is normal; Check if the finger cylinder is moving normally.